Specifications of the monitor
- weight is not more than 540 grams, size 170 х110х 60 mm
- a universal mount for any type and form of the surface
- 6 channels for the patient’s vital parameters registration:
- electrocardiogram (ECG),
- respiration,
- temperature,
- arterial blood saturation Sp02,
- invasive arterial blood pressure (IBP),
- non-invasive arterial blood pressure (NIBP).
- stand-alone power supply up to 14 hours
- PC connection via USB 2.0 interface with decoupling
- digital and graphical indication of the parameters being registered
- built-in wireless Wi-Fi (IEEE 802.11 b/g/n) adapter for remote data transmission
- SD card for off-line data recording and storing of the registered patient’s parameters consisting of:
- trends: 120 hours with 10 s resolution
- events alarm: 100 alarms with all parameters’ waveforms
- NIBP measurements: 1000 measurements
- manual records of the waveforms’ parameters:100 records 12 s each
- light and sound alarms
- color high contrast indication of the measurements’ results on the 5 inch built-in screen with 800х600 resolution
- comprehensive system of the monitor’s settings, control modes, user interface
- graphical and digital viewing mode of the measurements' results
Measurement channels
ECG channel in the on-line mode:
- Analyzes ST segment
- Detects pacemaker’s pulses
- Recognizes the following pathologies:
asystolia, ventricular fibrillation, ventricular flutter, paroxysmal ventricular tachycardia, accelerated ventricular rate, ventricular bradycardia, paroxysmal supraventricular tachycardia, accelerated supraventricular rate, supraventricular bradycardia, extreme tachycardia, extreme bradycardia, bradycardia, tachycardia, premature ventricular contraction (PVC), supraventricular premature contraction (SPVC), deformed QRS complex, interpolated (intercadent) premature ventricular contraction, interpolated (intercadent) supraventricular premature contraction, paired PVC, paired SPC, ventricular bigeminy, ventricular trigeminy, ventricular quadrigeminy, supraventricular bigeminy, supraventricular trigeminy, supraventricular quadrigeminy, PVC type R on T, polymorphic ventricular extra systole, skipped contraction, pause, irregular pulse, no pace detected.
Respiration channel uses impedance respiration measurement method in the range 0...120 inhales/exhales with error of ±2 breaths/min or ±2%
Temperature channel uses thermal resistance method in the range 0…50 °C with error of ±0,1 (without sensor)
Sp02 channel measures:
- Arterial blood saturation from 0 to 100% with error of ±2% in the range 70...100%
- Pulse from 20 to 300 beats/min with error of ±3 beats/min in the range 20…250 beats/min
NIBP channel (tonometer) measures pressure by the oscillometric method in the ranges 40…270; 10…210; 20…230 mm Hg with error of ±5 mm Hg
IBP channel measures pressure by the direct invasive pressure measurement method in the range -99…350 mm Hg with error of ±3%
Technical specifications
- Type of protection against electric shock - Class I
- Level of protection against electric shock - Type СF with defibrillator protection
- Operation mode - Continous
- Degree of protection against dangerous water penetration - IPX0
ECG cable (for 3 electrodes)
ECG cable for 3 chest electrodes
ECG cable (for 5 electrodes)
ECG cable for 5 chest electrodes
ECG electrodes
Disposable and multi-use ECG electrodes.
SpO2 Sensor
Sensor for measuring SpO2
ЗАПОЛНИТЕ ВИДЫ ИСПОЛНЕНИЯ